INSTALLATION GUIDE
RGBW ZONE COLOR CONTROLLER
IG022614-1.0
Safety & Warnings
Before you begin, read all warnings and installaon instrucons thoroughly.
Prior to installaon, verify all components are a compable system. Congure and pre-test your LED system prior to permanent installaon to ensure all
components are operang correctly. Install in accordance with the NEC and local regulaons.
1. Turn OFF 120~277VAC power at circuit breaker prior to installaon.
2. Remove the Input and Output cover ports of the zone receiver with a
#2 Phillips head screwdriver. Connect a compable constant voltage DC
driver to the receiver. See ‘Wiring Connecons’ and the ‘System Diagram.
3. Connect a compable RGBW xture to the receiver. Ensure not to
overload the receiver. In addion, do not exceed the maximum run
length of the xture. See ‘System Diagram.
4. Install addional components and accessories. Once complete, turn
circuit breaker ON.
Install in accordance with the Naonal Electric Code, and local regulaons.
This product is intended to be installed and serviced by a qualied,
licensed electrician.
Do not connect directly to high voltage 120V~277V power. Install with a
compable Class 2 constant voltage LED driver (power supply).
Only install compable LED drivers and xtures. Contact technical support
or visit the product page for compable products.
This product is rated for indoor installaon and is not protected against
moisture.
Proper heat dissipaon will prolong the working lifespan of this product.
Install in a well-venlated area free from explosive gases and vapors.
Ensure applicable wire is installed between driver, xture, and any controls
in between. When choosing wire, factor in voltage drop, amperage
rang, and type (in-wall rated, wet locaon rated, etc.). Inadequate wire
installaon could overhead wires, and cause a re.
Do not modify or disassemble this product beyond instrucons or the
warranty will be void.
Input Voltage 5VDC Built-in Lithium Baery
Transming Distance 99 .
Control Type
Pulse Width Modulaon (PWM). 4-channel
RGBW xtures.
Ambient Temperature † -4° ~ 131°F (-20° ~ 55°C)
Input / Output Voltage 5-24VDC constant voltage
Max Current Load 5A x 4CH Max 20A
Max Output Power
100W/240W/480W (5V/12V/24V)
Ambient Temperature
-22° ~ 131°F (-30° ~ 55°C)
Environment Indoor / dry locaon
RGBW Zone Remote
RGBW Zone Receiver
For full specicaons, see the ‘Specicaon Sheet’ available at the online
product page.
A ashing red indicator light on the zone remote implies a low baery.
To charge the remote, connect the included USB 2.0A/Mini-B cable to the
remote and to a 5VDC USB port.
Press the power buon on the remote and a blue indicator light will ash
to indicate charging. Once the indicator light turns green, charging is
complete.
Turn on the remote and the receiver.
Long press the ‘Learning ID’ buon on the receiver unl the receiver
beeps. Immediately long press a desired zone on the remote.
To indicate pairing, the receiver will long beep and a green indicator will
ash 3 mes on the remote.
Do not pair mulple remotes to a single receiver or pair mulple receivers to
a single zone. Doing so will cause the system to funcon improperly. Reset
the remote and receiver to factory sengs if improper pairing is performed.
Charging the Remote
Pairing the Remote with a Receiver
Reseng Remote & Receiver to Factory Sengs
To reset the remote, turn on remote and hold Power for three seconds. A
red indicator will ash red 3 mes and the remote will be reset.
To reset a single receiver, long press the ‘Learning ID’ buon on the
receiver (you will hear an inial beep). Connue holding for >8 seconds
unl the receiver long beeps. The receiver has now been reset to factory
sengs.
Installing the Receiver
Installation
Quick Specs
See the online product page for video
tutorials or contact technical support.
Need Addional Assistance?
Do not install product in an environment outside the listed ambient
temperature. Ensure adequate airow and heatsinking is considered
when mounng/installing.
WARNING
Shock Hazard. May result in serious injury or death.
Seitenansicht 0
1 2 3 4

Inhaltsverzeichnis

Seite 1 - Need Addional Assistance?

1 of 4INSTALLATION GUIDERGBW ZONE COLOR CONTROLLER IG022614-1.0Safety & WarningsBefore you begin, read all warnings and installaon instrucons th

Seite 2 - Zone Remote Operation

INSTALLATION GUIDERGBW ZONE COLOR CONTROLLER 2 of 4IG022614-1.0Control a single zonePress zone key 1-8 on the remote. To turn o zone, press Power. Co

Seite 3 - Mode Chart

3 of 4INSTALLATION GUIDERGBW ZONE COLOR CONTROLLER IG022614-1.0No. Press to Switch ColorPress to Switch Dynamic Mo

Seite 4 - System Diagrams

INSTALLATION GUIDERGBW ZONE COLOR CONTROLLER 4 of 4IG022614-1.0System DiagramsWBGR V+OutputDC+ DC−PowerAddressSengNURInstall applicable wire gauge /

Kommentare zu diesen Handbüchern

Keine Kommentare