Page 1 of 3
MounngQuick Specs
MAGNETIC DIMMABLE DRIVER INSTALLATION GUIDE
Before you begin, read all warnings and installaon instrucons thoroughly.
Safety & Warnings
• This driver must be installed in accordance with Arcle 450 of the
Naonal Electric Code, and local regulaons.
• This product is to be installed and serviced by a qualied electrician.
• This driver must be grounded to the green grounding wire.
• Install in a well-venlated area free from explosive gases and vapors.
• This product is rated for wet locaon/outdoor use (NEMA 3R enclosure).
• Only install compable LED dimmable xtures. Contact technical support
or visit the online product page for compable products.
• Ulize the wiring diagrams in this installaon guide for basic installaons.
• Do not modify or disassemble this product beyond instrucons or the
warranty will be void.
• Ensure applicable wire is installed between driver, xture, and any
controls in between. When choosing wire, factor in voltage drop,
amperage rang, and type (in-wall rated, wet locaon rated, etc.).
Inadequate wire installaon could overheat wires, and cause re.
• Do not test or install directly to 120VAC or through an ON/OFF
switch. This driver must be installed with a compable Magnec Low
Voltage (MLV) dimmer switch or the xture may become permanently
damaged. Visit the online product page for a list of compable dimmer
switches.
• Packaging will indicate output voltage, max load (de-rate 20%), and if
product meets Class 2 compliance. See dimmer switch for minimum
load recquirements.
Installaon
1. Turn power OFF at main circuit breaker.
2. Determine locaons to install the driver, xture and control. See ‘System Diagram.’
3. Remove driver faceplate and pop out wiring knockouts as needed. Install 1/2” Romex connectors/wire strains. Feed wire through Romex
connectors prior to making wiring connecons.
4. Aach the appropriate load to the dimmable driver.
5. Aach the 120VAC MLV dimmer switch to dimmable driver. Follow the install instrucons provided with the control.
6. Replace driver faceplate and turn power ON at main circuit breaker.
Install in accordance with the NEC and local regulaons. It is recommended to perform a dry test prior to permanent installaon to ensure all system
components are funconing properly.
Ensure applicable wire is installed between driver, xture, and dimmer. When choosing wire, factor in voltage drop, amp rang, and type to prevent
re or electric shock.
Auto Reset Breaker (20W - 100W Models)
Both primary and secondary circuits are protected with an automac
reset breaker. A tripped circuit is indicated by the load powering o.
Reset may take between 50 seconds and 5 minutes depending on load
size.
For proper heat dissipaon, mount vercally to
a sturdy surface, with the wiring compartment
poinng down. Install in a well-venlated
area free from explosive gases and vapors. A
mounng tab is located at the top of the driver.
Manual Reset Breaker (200W - 300W Models)
Both primary and secondary circuits are protected with a single reset
breaker in the event of an overload, surge, or short circuit. A tripped
circuit is indicated by a popped out, white edge. To reset, turn o main
power and push in buon.
If breaker trips (indicated by a white edge), turn
off main power and push in to reset breaker.
1
Breaker is now reset.
2
Boost Tap (200W - 300W Models)
200W & 300W models are equipped with a Boost Tap. Use the
Orange Boost Tap as an oponal voltage boost (roughly 1V) in place
of the Black (Line) wire if the xture is receiving noceable light
degradaon. Cap the exisng hot wire not in use.
L
B
From Driver
From Dimmer
Switch
Input Voltage 120VAC (Install with MLV dimmer)
Output Voltage See driver label for output voltage.
Max Load
See driver label for maximum load.
Ensure to de-rate the labeled load 20%.
See dimmer switch for min. load requirements.